PRO2026.3 Original from WB3FKP to MODS@ALLUS _____________________________________________________________________ Realistic PRO-2026 (100 Channel Mobile Programmable Scanner) Subject: Faster Scan Rate Mod Locate Y-201 (800J ceramic resonator, small blue rectangular componet near the Uniden UC1461 microprocessor) the clock resonator (frequency of 800K HZ) A speedup of 25% to 100% is possible, but more than that will cause problems A 1.0Mz to 1.6Mz ceramic resonator is needed, but if those can't be located use a 1M HZ quartz rock similar to Digikey numbers X-066 (HC-49a, 1.000mhz quartz crystal) and X-804 ( 1.00mhz crystal). This will provide a 25% speed increase. Replace the original Y-201 with one of these crystals.. de Mark WB3FKP @KB3QW.#EPA.PA _____________________________________________________________________